• • 上一篇    下一篇

多回路耦合CPL系统的几种失效情况分析

刘庆志,苗建印,张加迅,侯增祺   

  1. 中国空间技术研究院,中国空间技术研究院,中国空间技术研究院,中国空间技术研究院 北京100086 ,北京100086 ,北京100086 ,北京100086
  • 发布日期:2005-08-25

Experimental Investigation of Deprime of a CPL Coupled with Multi Loops

Liu Qingzhi Miao Jianyin Zhang Jiaxun Hou Zengqi (China Academy of Space Technology, Beijing 100086)   

  • Online:2005-08-25

摘要: 毛细抽吸两相流体回路(CPL,CapillaryPumpedLoop)在运行过程中可能会发生蒸发器失效的现象,严重影响了其可靠性。文章对CPL在变工况过程中可能引起蒸发器失效的一些因素进行了分析,并通过实验研究了一个多回路耦合CPL系统在某些热边界条件发生骤变时,系统的瞬态响应以及部分蒸发器失效的过程。

关键词: 毛细抽吸两相流体回路, 蒸发器, 失效分析, 热控制, 航天器

Abstract: Evaporator maybe deprimes when a Capillary Pumped Loop (CPL) is operating, which affects its reliability greatly. Deprime of evaporator may result from many factors which are analyzed in this paper. Moreover, a multiple loop coupling CPL experiment system is developed and tests are conducted to observe transient responses and deprime procedures of the system when some thermal boundary conditions change.