›› 2016, Vol. 36 ›› Issue (1): 35-42.doi: 10.3780/j.issn.1000-758X.2016.0008

Previous Articles     Next Articles

Experiment to improve the performance of an ECR neutralizer

 LUO  Li-Tao1,YANG  Juan1,*, JIN  Yi-Zhou1,SUN  Jun2,HAN  Fei2   

  1. 1College of Astronautics,Northwestern Polytechnical University,Xi′an 710072,China
    2Shanghai Key Laboratory of Space Intelligent Control,Shanghai 201109,China
  • Received:2015-11-12 Revised:2015-12-15 Published:2016-02-25 Online:2016-02-24

Abstract: The problem about domestic electron cyclotron resonance neutralizer is that electron beam can′t be extracted continuously at the variation of bias voltage.To overcome this, an experiment of neutralizer electron beam extraction was carried out to improve the performance through changing the antenna structure and adjusting the size of the electron extraction aperture. The experimental results show that the electron beam can be extracted continuously with the increasing  of the bias voltage. The propellant efficiency and electron energy loss for the improved neutralizer under the operation conditions are 1.659 8 and 126.3 W/A respectively,while 1.278 9 and 194.573 W/A respectively before neutralizer improvement. The plasma density within the neutralizer diagnosed by the Langmuir probe is in the range of 1.72×1017~12.1×1017 m-3.

Key words: electron cyclotron resonance(ECR), plasma, neutralizer, propellant efficiency, electron energy loss